2K 60FPS Endoscope Camera Module
2K 60FPS Endoscope Camera Module
video
2K 60FPS Endoscope Camera Module
2K 60FPS Endoscope Camera Module suppliers
1/2
<< /span>
>

2K 60FPS Endoscope Camera Module

The 2K 60FPS Endoscope Camera Module is a compact medical imaging module designed for integration into high-definition endoscopic camera systems. It combines real-time 1080P imaging, stable digital video transmission, configurable image controls, and multiple system interfaces for OEM medical imaging applications.

Product Overview

 

The 2K 60FPS Endoscope Camera Module is a compact medical imaging module designed for integration into high-definition endoscopic camera systems. It combines real-time 1080P imaging, stable digital video transmission, configurable image controls, and multiple system interfaces for OEM medical imaging applications.

 

Imaging Performance

 

Smooth Real-Time Imaging
High-frame-rate video provides smooth visualization during scope and instrument movement, supporting continuous observation during endoscopic procedures.

 

Flexible Image Adjustment
Configurable exposure, gain, gamma, contrast, brightness, sharpness, and white balance allow the image output to be adjusted for different endoscopic lighting conditions.

 

Enhanced Image Compensation
WDR, BLC and HLC functions help manage uneven illumination and high-contrast areas within the endoscopic field of view.

 

Camera Parameters

 

Synchronization method

Line-by-line scanning

Horizontal resolution

Number: 1080 (60P), 720 (120P) Maximum: 1100TVL (1080P)

S/N

Greater than 50dB (AGC off)

Positioning aperture

21MM

Video output signal

Digital: 3G-SDI, Analog: NTSC/PAL CVBS

On-screen display (OSD)

Available

Lens

Manual

Shutter speed

Automatic/Manual (1/60~1/60,000 (NTSC), 1/50~50,000 (PAL))

Gain control

Level 0~10

Digital slow shutter

Off/On (X2/X4/X8/X16/X32/X64)

Brightness

Level 0~20

WDR/ BLC

Off/BLC/HLC/WDR

Color density

Off/On

Contrast

Auto / Color / B&W / EXT

White balance

Automatic/Automatic EXT/Pushing/Manual

Gamma

Off/Low/Medium/High

Mirror/Flip

Off/On

Sharpness

X

B/R-Gain

Level 0~10

Digital amplification

Off/On

RS-485

Level 0~96

Language

District 24

Reset

English/Chinese/Korean/Japanese

Power

DC12V, maximum 2.5W

Size

P26*2.0mm(43mmT)

 

Mainboard Parameters

 

Input

3G-SDI

Output

HDMI/DVI/CVBS and loop SDI outputs

Power supply wattage

DC+10.8V~+13.2V

Power

Maximum 5.0w

PCB size

150mm X80mm

Operating Temperature

-10~+50C

Operating Humidity

5~90%RH

Input

Input: AC110~240V, Output: DC +12V/2A

 

p20260120190846ab99d
p20260120191111655c3

 

Image Control & User Operation

 

One-Touch White Balance
The dedicated white balance function enables quick image correction when lighting or optical conditions change.

 

Medical OSD Interface
The on-screen menu provides convenient access to camera settings and supports customized medical menus and multiple languages.

 

Five-Way Control
The five-way switch enables direct menu navigation and camera adjustment without requiring an external control device.

 

Image Freeze
The freeze function allows a current frame to be held for convenient image observation and system operation.

 

Video Interface & System Integration

 

Multiple Video Outputs
The module supports multiple video output configurations for connection with compatible displays, recording devices and image processing systems.

 

SDI Loop-Through
The loop SDI output facilitates signal distribution to additional compatible equipment within the endoscopic system.

 

RS-485 Communication
RS-485 provides an additional control interface for integration with external system controllers and OEM equipment.

 

OEM / ODM Customization

 

The INP-2KN1 is designed for integration into customized endoscopic camera systems. We can adjust key configurations according to the customer's optical, mechanical, electrical, and system requirements.

Optical Configuration
Lens and focal configuration
Field of view requirements
Working distance
Endoscope optical compatibility

Mechanical Configuration
Camera module dimensions
Board layout and mounting position
Housing integration
Cable routing and outlet position

Video & Electrical Interface
Video output configuration
Connector type
Cable length and arrangement
Power interface
RS-485 control connection

Image & Software Configuration
White balance and exposure settings
Gain, gamma and image enhancement
WDR/BLC/HLC settings
OSD menu layout
Logo and language configuration
Default parameter settings

OEM Development Process
Requirement Review → Review application, drawings, interfaces and optical requirements
Technical Evaluation → Confirm feasibility and recommended configuration
Sample Development → Prepare customized samples for evaluation
System Integration Test → Verify image output, interfaces and mechanical compatibility
Design Confirmation → Finalize approved specifications and configuration
Mass Production → Manufacture according to the approved sample and production specifications

 

Applications

 

Medical Endoscopic Imaging
For integration into endoscopic camera systems requiring high-definition real-time visualization.

 

Surgical Visualization Equipment
Suitable as an imaging module for surgical visualization platforms and related equipment.

 

OEM Medical Equipment
Designed for manufacturers developing customized endoscope cameras and medical imaging systems.

 

Quality Control & Testing

 

Each INP-2KN1 module is inspected through functional, image, interface, and reliability checks to verify consistent performance before shipment.

01/

Image Quality Inspection
Verify 1080P image output and frame rate
Check image clarity, color reproduction and noise
Test white balance, exposure and gain functions
Inspect WDR/BLC/HLC and other image adjustment functions

02/

Video Signal Testing
Verify 3G-SDI signal stability
Check HDMI/DVI/CVBS and loop SDI output
Confirm continuous video transmission without abnormal signal loss

03/

Interface & Control Testing
Test RS-485 communication
Verify five-way switch operation
Check OSD menu, language selection and image freeze functions
Confirm connector and cable connections

04/

Electrical & Functional Testing
Check power input and operating current
Verify camera and mainboard functions
Confirm proper operation under specified operating conditions

05/

Final Inspection
Each completed module is subjected to final functional inspection and appearance checking before packing and shipment.

06/

Aging Testing
Where required by the production or customer specification, modules can undergo continuous operation testing to identify early electronic or signal-related failures.

 

After-Sales Support

 

We provide technical support throughout the product lifecycle, from sample evaluation and system integration to batch production and after-sales service.

 

Technical Support
Our engineers assist with camera configuration, interface connection, image settings, and system integration during installation and commissioning.

 

Troubleshooting Support
For reported issues, our team reviews operating conditions, video output, power supply, connections, and system configuration to help identify the cause and provide corrective guidance.

 

Replacement & Warranty
Warranty and replacement services are provided according to the agreed sales terms. Confirmed product quality issues are handled through technical assessment and replacement or other agreed solutions.

 

Documentation Support
Technical specifications, operating instructions, test documents, and other available product documentation can be provided for system integration and maintenance.

 

Long-Term OEM Support
For OEM customers, we maintain the approved product configuration and provide ongoing technical communication for repeat orders, product updates, and integration requirements.

 

FAQ

 

Q: What should I consider when selecting an endoscope camera module?

A: Consider image performance, optical compatibility, video interfaces, module dimensions, power requirements, control methods, and system compatibility.

Q: Can this module be integrated into an existing endoscope system?

A: Yes. Integration can be evaluated based on your optics, mechanical space, interfaces, power supply, and control requirements.

Q: What information is needed for an OEM quotation?

A: Please provide the application, optical requirements, dimensions, interfaces, power supply, control requirements, and estimated order quantity.

Q: Can I test a sample before bulk production?

A: Yes. Samples can be provided for system integration and performance evaluation before production approval.

Q: What is the MOQ for OEM orders?

A: MOQ depends on the configuration and customization requirements. It will be confirmed during project evaluation.

Q: What is the OEM sample lead time?

A: Lead time depends on the required customization. Standard configurations generally require less development time than fully customized versions.

Q: Can the module be supplied under our own brand?

A: Yes. OEM branding and product identification can be discussed according to project requirements.

Q: How do you ensure consistency between samples and mass production?

A: The approved sample and confirmed technical specifications are used as production references for subsequent orders.

Q: Can you provide technical and compliance documents?

A: Yes. Relevant specifications, test reports, operating documents, and compliance certificates can be provided according to project requirements.

Q: Do you support long-term OEM supply?

A: Yes. We support repeat orders and ongoing technical coordination for approved OEM configurations.

Hot Tags: 2k 60fps endoscope camera module, China 2k 60fps endoscope camera module manufacturers, suppliers, factory

Send Inquiry

(0/10)

clearall