Endoscope Fixed Adapter

Your Professional Endoscope Fixed Adapter Supplier

 

Shenzhen INNOP Medical Instruments Co.,Ltd. was established in 2010. It is a national high-tech enterprise that integrates the research, production, sales and service of medical devices. As an international medical device manufacturer, INNOP collaborates with the Korean Medical Imaging Laboratory.INNOP adopts international management, continuously develops new technologies, is willing to accept new ideas, and continuously enhances its comprehensive strength. It moves forward steadily and rapidly, striving to become one of the most outstanding medical device manufacturers in China and abroad.

 

 

 
Why Choose Us

Our Certificate

We hold dozens of patents related to our products and have obtained the CE certification.

 

 

Production Equipment

There are two professional production lines, including medical pressure resistance tester, medical leakage current tester, medical grounding resistance tester, ultraviolet oven, illuminance meter, sound level meter, standard light box, LED rapid spectral analyzer, integrating sphere, etc.

Production Market

We have clients in Southeast Asia, Europe and Latin America. We have collaborated with over 40 clients for more than 5 years and have a good reputation among our customers.

Our Service

We offer professional services throughout the entire lifecycle of the equipment to ensure that customers receive an outstanding product experience and continuous value.

 

Advantages of Endoscope Fixed Adapter

 

Unmatched Stability & Zero Shake

By rigidly securing the camera to the endoscope, it prevents the micro-movements caused by manual handling. This guarantees blur-free, crystal-clear imaging.

01

Hands-Free/Single-Handed Operation

It frees up the practitioner’s hands. In medical fields like ENT or surgery, this allows the doctor to hold the scope with one hand while manipulating instruments or guiding the camera with the other.

02

Consistent View & Orientation

Fixed mounts maintain an optimal distance and alignment from the lens to the target. This is crucial for maintaining a specific field of view and tracking recurring industrial or medical inspection tasks.

03

Enhanced Documentation & Telementoring

Fixed adapters (like those mounting smartphones to endoscopes) make it effortless to record high-quality videos and photos. This improves training, allows for retrospective analysis, and enables remote sharing of procedures with specialists.

04

Cost-Effectiveness

It bridges the gap between specialized endoscopic camera towers and personal or off-the-shelf devices. This allows clinics and workshops to utilize available devices for high-definition visualization without needing to purchase expensive proprietary monitors.

05

 

Working principle of Endoscope Fixed Adapter

 

Working principle of Endoscope Fixed Adapter

Mechanical Coupling: It uses a mechanical clamping mechanism (such as a threaded collar, quick-release lever, or set screws) to rigidly lock onto the proximal eyepiece (or C-mount port) of the endoscope. This prevents the camera from twisting, slipping, or vibrating.

 

Optical Alignment (Relay): It holds the camera lens exactly concentric to the central axis of the endoscope's exit lens. This coaxial alignment ensures that the entire circular image produced by the endoscope projects perfectly onto the camera's image sensor (CCD, CMOS, or phone camera lens).

 

Fixed Focus and Light Tightness: The adapter maintains a precise, unmoving distance (air gap) between the endoscope's eyepiece and the camera. This fixed focal distance keeps the image parfocal, meaning the camera stays permanently in focus if the endoscope's own view is already focused. It also forms a light-tight seal, blocking ambient room light from washing out the video feed.

 

By Application of Endoscope Fixed Adapter

 

The endoscope camera adapters market is primarily driven by applications in healthcare and industrial inspection. In the medical sector, these adapters facilitate high-quality imaging during diagnostic and surgical procedures, including gastrointestinal, respiratory, and orthopedic interventions. The increasing prevalence of chronic diseases and the shift toward minimally invasive techniques are fueling demand for advanced endoscopic imaging solutions. Hospitals, clinics, and diagnostic laboratories are adopting these adapters to improve procedural outcomes and patient safety.

 

Industrial applications encompass inspection, maintenance, and quality control in sectors such as manufacturing, aerospace, and energy. Endoscope camera adapters enable detailed visualization of hard-to-reach areas, aiding in preventive maintenance and defect detection. The growing need for non-destructive testing and compliance with safety standards is expanding the industrial application base. The versatility and precision provided by these adapters are critical factors driving their adoption across various industrial processes.

 

The integration of digital and high-definition imaging technologies has further enhanced the utility of endoscope camera adapters in both sectors. As automation and smart inspection systems become more prevalent, the demand for compatible, high-performance adapters is expected to rise.

 

 

Maintain of Endoscope Fixed Adapter

Cleaning your endoscope
It's important to establish an effective manual cleaning protocol prior to high-level disinfection. A significant amount of foreign material and organisms are removed from the endoscope at this stage. Manual cleaning should begin as soon as the scope is removed from the patient.

 

When the procedure is completed
• Depress air/water valve to force water through the water channel.

• Place finger over the air/water valve to force air through the air channel.

• Depress suction valve with distal tip in cleaning solution, then remove distal tip from solution and suction air. Alternating air and cleaning solution will remove more debris from internal lumens.

• Endoscopes with air/water cleaning adapters: This adapter allows continuous air or water through both the air and water channels (not to be confused with an all-channel irrigator that could flood your light source). Turn off air pump, remove air/water valve and attach cleaning adapter. Turn air pump on and allow air through channels for 30-45 seconds. Depress valve to allow water to run through channels.

• Turn off power to the light source, video processor or camera, and then detach the endoscope. If indicated, place protective cap over video connective ports.

• Wipe excess debris off endoscope with gauze sponges and enzymatic cleaning solution. Carefully transport your endoscope and accessories to a cleaning station for thorough cleaning and disinfection.

Maintain of Endoscope Fixed Adapter

 

Drying

 

Flush endoscope with 70% isopropyl alcohol. The alcohol mixes with the remaining water on channel surfaces and encourages evaporation.

 

If forced air is available, attach to irrigation adapters for 20-30 minutes and hang endoscope.

 

Remove irrigation adapters. Make sure exterior of the endoscope is dry.

 

Dry and hang biopsy forceps with jaws open. Dry all other endoscope accessories.

 

Apply a small amount of silicone oil to O-rings on valves.

 

Your endoscope should be stored in a hanging position, and never in the storage case. In a flat, coiled position, water could pool in the channel--an ideal site for bacterial growth. Choose a well-ventilated area in your hospital, away from excessive traffic.

 

 

 

FAQ

 

 

Q: What are the two types of flexible endoscopes?

A: Components and Types of Flexible Endoscopes
Gastroscopes – Used to examine the upper digestive tract. Colonoscopes – Used during colonoscopy procedures to view the large intestine.

Q: How many days bed rest after endoscopy?

A: The initial recovery from sedation or anesthesia typically takes a few hours for most patients. Mild symptoms such as throat soreness or bloating often subside the same day or within 24 hours. Full recovery, including the ability to resume all normal activities, usually happens within a day.

Q: What is the latest technology for endoscopy?

A: AI-assisted endoscopy is one of the most exciting developments in the field: a) Computer-aided Detection (CAD): AI algorithms can analyse endoscopic images in real time. Helps detect polyps, lesions, and early-stage cancers with high accuracy.

Q: What not to do after an endoscopy?

A: For the first 24 hours after your procedure:
Do not drink alcohol. Do not drive or operate heavy machinery. Avoid sedatives, tranquilizers, or sleeping medications. Sedation may affect your alertness, coordination, and concentration for up to 24 hours.